E5ZE Temperature Controller Read Protocol
Read Cooling Coefficient (Sequence No. 123 (Hex 007B))
Reads the cooling coefficients and stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
522
+0
Number of send data words
+1
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Unit No. (2 digits Hex)
+0
Number of receive data words
+1
Cooling coefficient
+2
Cooling coefficient
~
+8
Cooling coefficient
Offset
Contents (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Channel 0
Cooling coefficient (4 digits BCD)
+2
Channel 1
Cooling coefficient (4 digits BCD)
+8
Channel 7
Cooling coefficient (4 digits BCD)
Unit No.
0002 (fixed)
00 to 0F
Channel 0
Channel 1
~
Channel 7
0009
0000 to 0100
0000 to 0100
•
•
•
0000 to 0100
Appendix H
Data
Data