Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 242

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

Protocol Conversion
System Configuration Patterns
Sending FINS Messages Using CMND(490) in CPU Unit's Ladder Program
CPU Bus-to-Serial
Serial Communications Unit/Board
CPU Unit
Protocol
FINS header
conversion
CompoWay/F
command
CompoWay/F Slave-compatible Components
Temperature Con-
trollers
Timer/Counters
Digital Panel Meters
Smart Sensors
Cam Positioners
Safety Controllers
The Board/Unit converts the FINS messages to CompoWay/F protocol for
sending in this operation.
Access from CPU Unit (on the Same PLC)
CMND(490)
FINS message
CompoWay/F
2803
command
RS-485 (CompoWay/F)
CompoWay/F-compatible
OMRON component
Component
Thermac NEO
Thermac R
Plug-in Temperature Control-
lers
Digital Controller Boards
Digital Controllers
Timers/Counters
Digital Panel Meters
Digital Load Cell Meters
Digital Rotary/Pulse Meters
Digital Incrementing Panel
Meters
Digital Time Interval Meters
Digital Temperature/Process
Meters
ZX Communications Interface
Units
---
---
Details
OMRON components connected serially to
the Serial Communications Board/Unit
using CompoWay/F can be accessed from
a CPU Unit in the same PLC.
Section 6-5
Model series
E5GN (G components)
E5CN
E5EN
E5AN
E5AR
E5ER
E5ZN
E5ZM
ES100X
H8GN (G components)
K3GN (G components)
K3NX
K3NV
K3NR
K3NP
K3NC
K3NH
ZX-SF11
3F88L-160, 3F88L-162
F3SX
Routing tables to
treat serial
communications
path as network
Optional
213

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents