N 3Z4L Laser Micrometer Protocol - Omron SYSMAC CS1W-SCB41-V1 Operation Manual

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

The 3Z4L Laser Micrometer Protocol is used to make various settings or control remotely the Laser Micrometer
connected to the Serial Communications Unit/Board via RS-232C cable.
Protocol Configuration
The configuration of the 3Z4L Laser Micrometer Protocol is shown below.
Sequence
Communications sequence
No.
400 (0190)
3Z4L clear
401 (0191)
Memory switch set
402 (0192)
mm unit set
403 (0193)
E unit set
404 (0194)
Calibration set
405 (0195)
Calibration release
406 (0196)
Program number set
(3000-series)
407 (0197)
Measurement condition set
(3000-series)
408 (0198)
Measurement condition
release (3000-series)
409 (0199)
Measurement condition list
request (3000-series)
410 (019A)
Single run measurement start
(3000-series)
411 (019B)
Zero run measurement start
(3000-series)
412 (019C) Continuous measurement start
(scan) (3000-series)
413 (019D) Continuous measurement start
(interrupt) (3000-series)
414 (019E)
Measurement termination
(3000-series)
415 (019F)
Data request (3000-series)
Appendix N
3Z4L Laser Micrometer Protocol
name
Resets errors, data, analog output,
decision result and places the Laser
Micrometer into standby.
Sets memory switches and the area
for the work position LED.
Sets the display unit to mm.
Sets the display unit to E.
Calibrates the Laser Micrometer.
Calibration setting release.
Releases the calibration of the Laser
Micrometer.
Switches the program number to a
specified number.
Sets measurement conditions.
Releases measurement conditions
that have been set.
Requests the measurement condi-
tions that have been set and other
settings.
When the sample measurement con-
dition is from 1 to 999, performs a sin-
gle run measurement and requests
the measurement results.
If the sample measurement condition
is zero, starts a zero run measure-
ment.
Starts a continuous measurement.
The scan notification method is used
for receive data.
Starts a continuous measurement.
The interrupt notification method is
used for receive data.
Measurement termination (3000-
series)
Terminates a continuous measure-
ment.
Requests display data in the idle
measurement status or the latch data
generated by the measurement com-
mand.
Function
Send word
allocation
Ladder interface
Notes
Receive
word allo-
cation
No
No
Yes
No
No
No
No
No
Yes
No
No
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
2
No
*1
No
No
Yes
633