Auxiliary Area and CIO Area Allocations
Status Area
Words
Boards
Units
(CS Series only)
(CS/CJ Series)
Port 1
Port 2
Port 1
CIO 1901
n + 1
CIO 1902
n + 2
CIO 1903
n + 3
CIO 1904
n + 4
130
CPU Bus Unit Area
CIO 1500 to CIO 1899
n = CIO 1500 + 25 × unit number
Unit No.
Unit No. 0
CIO 1500 to CIO 1524
Unit No. 1
CIO 1525 to CIO 1549
Unit No. 2
CIO 1550 to CIO 1574
Unit No. 3
CIO 1575 to CIO 1599
Unit No. 4
CIO 1600 to CIO 1624
Unit No. 5
CIO 1625 to CIO 1649
Unit No. 6
CIO 1650 to CIO 1674
Unit No. 7
CIO 1675 to CIO 1699
Unit No. 8
CIO 1700 to CIO 1724
Unit No. 9
CIO 1725 to CIO 1749
Unit No. A
CIO 1750 to CIO 1774
Unit No. B
CIO 1775 to CIO 1799
Unit No. C
CIO 1800 to CIO 1824
Unit No. D
CIO 1825 to CIO 1849
Unit No. E
CIO 1850 to CIO 1874
Unit No. F
CIO 1875 to CIO 1899
The Status Area is used for status information input from Serial Communica-
tions Board or Unit to the CPU Unit. The Status Area is where the Serial Com-
munications Board or Unit set communications status, the transmission
control signal status, and the transmission error status.
Bit
Port 2
02 to 15
Reserved
01
1: Error log EEPROM error
00
1: Protocol data error
00 to 15
Reserved
00 to 15
Reserved
00 to 15
Reserved
Words
n + 1 to n + 4: Unit status
n + 5 to n + 8: Port 1 status
n + 15 to n + 18: Port 2 status
n = CIO 1500 + 25 × unit number
Contents
0: Error log EEPROM normal
0: Protocol data normal