Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 550

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

E5ZE Temperature Controller Read Protocol
Note The read data will be 0000 for all channels for which HB and HS alarms are not enabled and for all chan-
nels for which control is stopped.
Read Dead Band/Overlap Band (Sequence No. 122 (Hex 007A))
Reads the dead bands/overlap bands and stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Offset
Contents (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Channel 0
Heater current
(4 digits BCD)
+2
Channel 0
SSR leakage current
(4 digits BCD)
+15
Channel 7
Heater current
(4 digits BCD)
+16
Channel 7
SSR leakage current
(4 digits BCD)
+0
Number of send data words
(Undefined)
+1
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Unit No. (2 digits Hex)
+0
Number of receive data words
+1
Dead band/overlap band
+2
Dead band/overlap band
~
+8
Dead band/overlap band
Offset
Contents (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Channel 0
Dead band/overlap band
(4 digits BCD)
+2
Channel 1
Dead band/overlap band
(4 digits BCD)
+8
Channel 7
Dead band/overlap band
(4 digits BCD)
0011 (0017 decimal)
0000 to 0500
0000 to 0500
0000 to 0500
0000 to 0500
Unit No.
0002 (fixed)
00 to 0F
Channel 0
Channel 1
~
Channel 7
0009
0000 to 0999
F indicates a number.
0000 to 0999
F indicates a number.
0000 to 0999
F indicates a number.
Appendix H
Data
Data
Data
521

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents