Ricoh G188 Service Manual page 604

Table of Contents

Advertisement

Engine Service Mode
004 Cancellation Time
005 Counter Clear Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
001 Permissible Number
002 Detect Time
G188/G189
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if
correct user ID and password are entered.
Determines the length of time that the
system waits for correct input of the user ID
and password after a lockout has occurred.
*CTL
This setting is used only if SP5413-3 is set
to "1" (on).
[1 to 999 / 60 / 1 min./step]
*CTL
Not Used
Switches on/off masking of continuously
used IDs and passwords that are identical.
*CTL
[0 or 1 / 0 / -]
0: Off, 1: On
Sets the length of time for excluding
continuous access for identical user IDs
*CTL
and passwords.
[0 to 60 / 15 / 1 min./step]
Sets the number of attempts to attack the
system with random passwords to gain
*CTL
illegal access to the system.
[0 to 100 / 30 / 1 attempt/step]
Sets the time limit to stop a password
attack once such an attack has been
*CTL
detected.
[1 to 10 / 5 / 1 sec./step]
8-192
SM Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

G189

Table of Contents