146 Glossy: Middle Thick
148 1bin: Plain
150 F: 1bin: Plain
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Fusing: Center
002 Fusing: Ends
003 Pressure
[Forced Ready Setting]
1108
Japan use only
001 ON/OFF
002 Target Voltage Ratio
003 Measured Voltage Ratio
005 Temp: Threshold
006 Auto Off Timer
007 Time
SM Appendix
*ENG
[120 to 170 / 145 / 1 deg/step]
[130 to 180 / P2c: 150, P2d: 155 / 1
*ENG
deg/step]
*ENG
[120 to 170 / 135 / 1 deg/step]
[–20 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One
-
heats the center of the heating roller and
the other heats both ends of the heating
roller.
-
[–10 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One heat
s the center of the heating roller and the
-
other heats both ends of the heating roller.
[0 or 1 / 0 / 1 ]
*ENG
0: OFF, 1: ON
*ENG
[85 to 115 / 92 / 1 %/step]
*ENG
[70 to 120 / 100 / 1 %/step]
*ENG
[10 to 32 / 17 / 1 deg/step]
*ENG
[0 to 255 / 0 / 1 min/step]
[7 to 60 / P2c: 14.0, P2d: 24.0 / 0.1
*ENG
sec/step]