Engine Service Mode
007 Separation DC: 1200: 1st Side
[Special 3: Environment Correction]
2880
Thick 1: 154 mm/sec, 1200: 77 mm/sec
001 Separation DC: Thick 1: 1st Side
002 Separation DC: Thick 1: 2nd Side
003 Paper Transfer: Thick 1: BW: 1st Side
004 Paper Transfer: Thick 1: BW:2nd Side
005 Paper Transfer: Thick 1: FC: 1st Side
006 Paper Transfer: Thick 1: FC:2nd Side
007 Separation DC: 1200: 1st Side
009 Paper Transfer: 1200: BW: 1st Side
011 Paper Transfer: 1200: FC: 1st Side
[OPC Drum Brake Time]
Adjusts the time when the OPC drum motor reverses from normal rotation after
2901
job end. DFU
Plain: 205 (P2c)/230 (P2d) mm/sec, Thick 1: 154 mm/sec, Thick 2&Fine: 77
mm/sec
001 Plain
002 Thick 1
003 Thick 2 & FINE
[OPC Drum Reverse Time]
2902
Adjusts the time for how long the OPC drum motor reverses after job end. DFU
001 All: BW
G188/G189
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[300 to 1500 / 500 / 10 msec/step]
*ENG
*ENG
*ENG
[0 to 200 / 30 / 10 msec/step]
8-128
[1 to 60 / 26 / 1 /step]
[1 to 60 / 32 / 1 /step]
[1 to 60 / 11 / 1 /step]
[1 to 60 / 11 / 1 /step]
[1 to 60 / 26 / 1 /step]
[1 to 60 / 11 / 1 /step]
[1 to 60 / 1 / 1 /step]