Engine Service Mode
[ITB Idling Number]
3520
Specifies the number of the ITB idling rotation for each condition.
001 Temperature: H
002 Temperature: M
003 Temperature: L
004 Temperature: L: Power ON
[Temperature Threshold]
Specifies the threshold temperature for each condition. These settings affect
3521
the conditions of SP3-520.
t1: Threshold between L (low temp.) and M (medium temp.)
t2: Threshold between M (medium temp.) and H (high temps)
001 Threshold: t2
002 Threshold: t1
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
3522
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting
003 Temperature Range
004 Relative Humidity Range
005 Absolute Humidity Range
100 [Rapi_timer]
G188/G189
*ENG
*ENG
[0 or 3 / 0 / 1 revolution/step]
*ENG
*ENG
*ENG
[20 or 30 / 25 / 1 deg/step]
*ENG
[0 or 15 / 15 / 1 deg/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
8-168
3
/step]