Ricoh G188 Service Manual page 365

Table of Contents

Advertisement

No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Undefined error
CTL
992
Defective software program
D
An error undetectable by any other SC code occurred
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
995
D
CPM setting error
Defective BICU
NVRAM Replacement error
-001
1.
Install the previous NVRAM.
2.
Input the serial number with SP5811-004, and turn the main power
switch off/on.
Defective NVRAM
Defective controller
-002
1.
Update the controller firmware.
2.
Install a new NVRAM, and turn off and on the main power switch
after SC995-002 has occurred.
Incorrect type controller installed
Defective controller
-003
Replace the controller board with the correct type.
Incorrect model controller installed.
-004
Replace the controller board with the correct model.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
998
CTL
Application start error
D
No applications start within 60 seconds after the power is turned on.
SM Appendix
Service Call Conditions
3-69