007 Execution Flag: C
008 Execution Flag: Y
3041
[Process Control Type]
Voltage Control
001
Enables or disables potential control.
LD Power Control
002
Selects the LD power control mode.
Pre-ACC
004
Selects the process control mode that is done before ACC.
3043
[TD Adjustment Mode]
Repeat Number: Power ON
Specifies the maximum number of repeats of the toner density adjustment at
power on.
0: Disabled, 1 to 3: Repeat number,
001
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
SM Appendix
*ENG
This flag is cleared after executing TD
sensor initialization.
*ENG
[0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the
*ENG
charge DC bias and development DC bias
set with SP2-005 and SP2-229.)
1: CONTROL
[0 or 1 / 1 / 1/step] Alphanumeric
*ENG
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
[0 to 2 / 2 / 1/step]
0: Not Executed
*ENG
1: Process Control
2: TC Control (TD Adjustment)
3: Not used
*ENG
[0 to 9 / 4 / 1 time/step]
8-137
Engine Service Mode
G188/G189