004 Environmental Target: Y
[Charge AC Current: MM] Charge Roller AC Current Adjustment for MM
(Color)
2009
Displays/sets the AC current target of the charge roller for MM environment
(Middle temperature and Middle humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: MH] Charge Roller AC Current Adjustment for MH
(Color)
2010
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: HH] Charge Roller AC Current Adjustment for HH
(Color)
2011
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
SM Appendix
*ENG
*ENG
*ENG
[0 to 3 / P2c: 1.56, P2d: 1.76 / 0.01
mA/step]
*ENG
*ENG
*ENG
*ENG
[0 to 3 / P2c: 1.64, P2d: 1.83 / 0.01
mA/step]
*ENG
*ENG
*ENG
[0 to 3 / P2c: 1. 66, P2d: 1.85 / 0.01
mA/step]