Ricoh G188 Service Manual page 297

Table of Contents

Advertisement

3. APPENDIX: SERVICE CALL CONDITIONS
3.1 SERVICE CALL CONDITIONS
3.1.1 SUMMARY
The "SC Table" section shows the SC codes for controller errors and other errors. The latter
(not controller errors) are put into four types. The type is determined by their reset
procedures. The table shows the classification of the SC codes.
Key
Controller
The error has occurred in the
CTL
errors
controller.
The error involves the fusing
unit. The machine operation is
A
disabled. The user cannot reset
the error.
The error involves one or some
specific units. The machine
B
operates as usual, excluding
the related units.
The error is logged. The
Other errors
SC-code history is updated.
C
The machine operates as
usual.
The machine operation is
disabled. You can reset the
machine by turning the main
D
power switch or main switch off
and on. If the error occurs
again, the same SC code is
displayed.
SM Appendix
Definition
See "Troubleshooting Procedure"
in the table.
Turn the main switch off and on.
Reset the SC (set SP5-810-1).
Turn the main switch off and on.
Turn the main power switch off
and on.
The SC will not show. Only the
SC history is updated.
Turn the main power switch or
main power switch off and on.
3-1
Service Call Conditions
Reset Procedure
G188/G189