Ricoh G188 Service Manual page 455

Table of Contents

Advertisement

Absolute Humidity:
005
Threshold 3
Absolute Humidity:
006
Threshold 4
007 Current Temp.: Display
Current Relative
008
Humidity: Display
Current Absolute
009
Humidity: Display
Previous Environmental:
010
Display
011 Previous Temp.: Display
Previous Relative
012
Humidity: Display
Previous Absolute
013
Humidity: Display
[Charge AC Control: Setting] DFU
2014
Specifies the charge AC control interval or thresholod for each condition.
001 Exec Interval: Power ON
002 Exec Interval: Print
003 Page Interval
SM Appendix
Changes the humidity threshold
*ENG
between MM and MH.
[0 to 100 / 18.0 / 0.01 g/m
Changes the humidity threshold
*ENG
between MH and HH.
[0 to 100 / 24.0 / 0.01 g/m
Displays the current temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the current relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
Displays the absolute humidity.
*ENG
[0 to 100 / 0 / 0.01 g/m
Displays the previous environmental
condition, which is measured in absolute
*ENG
humidity.
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Displays the previous temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the previous relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
Displays the previous absolute humidity.
*ENG
[0 to 100 / 0 / 0.01 g/m
*ENG
[0 to 2000 / 500 / 1 page/step]
*ENG
*ENG
[0 to 500 / 10 / 5 page/step]
8-43
Engine Service Mode
3
/step]
3
/step]
3
/step]
3
/step]
G188/G189

Advertisement

Table of Contents
loading

This manual is also suitable for:

G189