No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: C
The PFGATE ON signal does not assert within 5 seconds after
236
D
processing the image in normal job or MUSIC for start position [C].
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: C
The PFGATE ON signal still asserts within 5 seconds after
237
D
processing the image in normal job or MUSIC for end position [C].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
240
C
LD error: Bk
241
C
LD error: Y
242
C
LD error: M
243
C
LD error: C
The BCU detects LDB error a few times consecutively when LDB unit
turns on after LDB initialization.
-
-
Worn-out LD
Disconnected or broken harness of the LD
1.
Replace the harness of the LD.
SM Appendix
Service Call Conditions
3-9
G188/G189