Ricoh G188 Service Manual page 485

Table of Contents

Advertisement

a: adjustment twice). The timing for line position adjustment depends on the
combinations of several conditions.
Time 2
012 Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
Page: Power
ON:BW+FC
013 Adjusts the threshold of the line position adjustment for BW and FC printing
mode at power-on. The line position adjustment is done when the number of
outputs in BW and color printing mode reaches the value specified with this SP
and the condition of SP2-193-008 or SP2-193-009 is satisfied.
2194
[MUSIC Execution Result] Line Position Adjustment: Execution Result
001 Year
002 Month
003 Day
004 Hour
005 Minute
006 Temperature
007 Execution Result
008 Number of Execution
009 Number of Failure
010 Error Result: M
011 Error Result: C
SM Appendix
*ENG
[1 to 9999 / 600 / 1 minute/step]
*ENG
[0 to 999 / 200 / 1 page/step]
*ENG
[0 to 99 / 0 / 1 year/step]
*ENG
[1 to 12 / 1 / 1 month/step]
*ENG
[1 to 31 / 1 / 1 day/step]
*ENG
[0 to 23 / 0 / 1 hour/step]
*ENG
[0 to 59 / 0 / 1 minute/step]
*ENG
[0 to 100 / 0 / 1 deg/step]
[0 or 1 / 0 / 1 /step]
*ENG
0: Completed successfully, 1: Failed
*ENG
[0 to 999999 / 0 / 1 times/step]
*ENG
[0 to 999999 / 0 / 1 times/step]
*ENG
[0 to 9 / 0 / 1 /step]
0: Not done
*ENG
8-73
Engine Service Mode