Ricoh G188 Service Manual page 574

Table of Contents

Advertisement

Engine Service Mode
[Pixel Adj. Sheet Counter: Display]
3510
Displays the total page counter for each adjustment mode.
001 Potential Control: BW
002 Potential Control: FC
003 Power ON: BW
004 Power ON: FC
005 MUSIC: BW
006 MUSIC: FC
007 Vsg Adj.
008 Charge AC Control
009 MUSIC: Power ON: BW
010 MUSIC: Power ON: FC
[Execution Interval: Setting]
3511
Adjusts the threshold for each adjustment mode.
001 Job End: Potential Control: BW
002 Job End: Potential Control: FC
003 Interrupt: Potential Control: BW
004 Interrupt: Potential Control: FC
005 Initial: Potential Control: BW
006 Initial: Potential Control: FC
007 Vsg Adj. Counter
008 Charge AC Control Counter
019 Environmental Correction
G188/G189
*ENG
*ENG
*ENG
*ENG
[0 to 2000 / 0 / 1 page/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 2000 / 250 / 1 page/step]
*ENG
[0 to 2000 / 100 / 1 page/step]
*ENG
[0 to 2000 / 500 / 1 page/step]
*ENG
[0 to 2000 / 200 / 1 page/step]
*ENG
[0 to 2000 / 250 / 1 page/step]
*ENG
[0 to 2000 / 100 / 1 page/step]
*ENG
[0 to 2000 / 0 / 1 page/step]
*ENG
*ENG
[0 or 1 / 1 / 1 /step]
8-162