Ricoh G188 Service Manual page 567

Table of Contents

Advertisement

017 Total Page Setting: S
018 Total Page Setting: M
019 Total Page Setting: L
020-023 Adjusts the threshold for SP3-251-024 to -027.
020 Total Page Setting: S2
021 Total Page Setting: M2
022 Total Page Setting: L2
024-027 Displays the latest coverage ratio for each color.
024 Latest Coverage: Bk
025 Latest Coverage: M
026 Latest Coverage: C
027 Latest Coverage: Y
Displays the threshold of whether to perform developer churning or not.
028
DevMix Threshold
[ID Sensor Detection Value: Voffset]
3311
Displays the ID sensor (regular) offset voltage for Vsg adjustments.
001 Voffset reg: Bk
002 Voffset reg: M
003 Voffset reg: C
004 Voffset reg: Y
005-007 Displays the ID sensor (diffusion) offset voltage for Vsg adjustments.
005 Voffset dif: M
006 Voffset dif: C
SM Appendix
*ENG
[1 to 100 / 10 / 1 sheet/step]
*ENG
[1 to 500 / 10 / 1 sheet/step]
*ENG
[1 to 999 / 50 / 1 sheet/step]
*ENG
[1 to 100 / 20 / 1 sheet/step]
*ENG
[1 to 500 / 10 / 1 sheet/step]
*ENG
[1 to 999 / 50 / 1 sheet/step]
*ENG
*ENG
[0 to 100 / - / 0.01 %/step]
*ENG
*ENG
*ENG
[0 to 100 / 20 / 1 %/step]
*ENG
[0 to 5 / 0 / 0.01 V/step]
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
*ENG
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
8-155
Engine Service Mode
G188/G189