Engine Service Mode
Specifies the developer agitation time for each color at the developer
initialization. DFU
001 Agitation Time: Bk
002 Agitation Time: M
003 Agitation Time: C
004 Agitation Time: Y
005-008 Sets the execution flag of the developer initialization for each color. DFU
005 Execution Flag: Bk
006 Execution Flag: M
007 Execution Flag: C
008 Execution Flag: Y
009 Prohibition
[Toner Replenishment Mode] DFU
3022
Specifies the toner supply time for each color in the toner supply mode.
001 Number: Bk
002 Number: M
003 Number: C
004 Number: Y
005-008 Sets the execution flag for the toner supply mode for each color.
005 Execution Flag: Bk
006 Execution Flag: M
G188/G189
*ENG
*ENG
[0 to 200 / 30 / 1 sec/step]
*ENG
*ENG
*ENG
[0 or 1 / 0 / 1/step]
*ENG
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD
*ENG
sensor initialization.
*ENG
Enables or disables developer
initialization. DFU
*ENG
[0 or 1 / 0 / 1/step]
0: Enable, 1: Disable
*ENG
[0 to 30 / 8 / 1 sec/step]
*ENG
[0 to 30 / 6 / 1 sec/step]
*ENG
*ENG
*ENG
[0 or 1 / 0 / 1/step]
0: Flag OFF, 1: Flag ON
*ENG
8-136