Engine Service Mode
Repeat Number: Initialization
Specifies the maximum number of repeats of the toner density adjustment at
the developer initialization.
0: Disabled, 1 to 3: Repeat number,
002
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: Non-use
Specifies the maximum number of repeats of the toner density adjustment in
stand by mode.
0: Disabled, 1 to 3: Repeat number,
003
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: ACC
Specifies the maximum number of repeats of the toner density adjustment at
ACC.
0: Disabled, 1 to 3: Repeat number,
004
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: Recovery
005
Not used
Repeat Number: Job End
Specifies the maximum number of repeats of the toner density adjustment at
006
job end.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
G188/G189
*ENG
[0 to 9 / 3 / 1 time/step]
*ENG
[0 to 9 / 0 / 1 time/step]
*ENG
[0 to 9 / 3 / 1 time/step]
*ENG
[0 to 9 / 0 / 1 time/step]
*ENG
[0 to 9 / 4 / 1 time/step]