1112
[Environmental Correction: Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction
003 Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of this
SP is added to the heating roller temperature.
High Temp. Correction
004 Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of this
SP is subtracted from the heating roller temperature.
Reference Temp
005 Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of this
SP is subtracted from the heating roller temperature.
006 Low Temp Correction a
007 Reference Temp Correction a
008 High Temp Correction a
009 Low Temp Correction b
010 Reference Temp Correction b
011 High Temp Correction b
SM Appendix
[0 or 1 / 1 / 1]
0: OFF, 1: ON
*ENG
[10 to 23 / 17 / 1 deg/step]
*ENG
[24 to 40 / 30 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[15 to 25 / 20 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 10 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]