11.1.8 Acceleration time [BFM #14018, BFM #14218]

This parameter sets a time for the operation speed to reach the maximum speed from zero.
BFM Number
X-axis
BFM #14018
BFM #14218
Note
• The acceleration time becomes 1 ms when set at 0 ms or lower, and becomes 5000 ms when set at 5001
ms or higher.
• Set the time within the range from 64 (greater than 64) to 5000 ms in the approximate S-shaped
acceleration/deceleration.

11.1.9 Deceleration time [BFM #14020, BFM #14220]

This parameter sets the time for the operation speed to reach to zero from the maximum.
BFM Number
X-axis
BFM #14020
BFM #14220
Note
• The acceleration time becomes 1 ms when set at 0 ms or lower, and becomes 5000 ms when set at 5001
ms or higher.
• Set the time within the range from 64 (greater than 64) to 5000 ms in the approximate S-shaped
acceleration/deceleration.

11.1.10 Interpolation time constant [BFM #14022, BFM #14222]

This parameter sets the time for the interpolation operation speed to reach the maximum speed from zero
(acceleration) or to reach zero from the maximum speed (deceleration).
BFM Number
X-axis
BFM #14022
BFM #14222
Note
The acceleration time becomes 1 ms when set at 0 ms or lower, and becomes 5000 ms when set at 5001 ms
or higher.

11.1.11 Zero return speed (High Speed) [BFM #14025, #14024, BFM #14225, #1424]

This parameter sets the mechanical zero return operation speed (high speed) [DOG, Stopper #1].
BFM Number
X-axis
BFM
BFM
#14025,
#14225,
#14024
#14224
*1.
Refer to the section shown below for details on the user units and converted pulse data.
Note
• Set the zero return speed (high speed) at or below the maximum speed.
When the zero return speed (high speed) exceeds the maximum speed, 20SSC-H operates at the
maximum speed.
• Speed change commands in positioning operation change the zero return speed (high speed) into a preset
value.
108
Y-axis
Setting range: 1 to 5000 ms
Y-axis
Setting range: 1 to 5000 ms
→ For details on the interpolation time constant, refer to Section 7.2
Y-axis
Setting range: 1 to 5000 ms
→ For details on the mechanical zero return, refer to Section 8.1
Y-axis
Setting range: 1 to 2,147,483,647 (user unit)
Set the value within 1 to 50,000,000Hz in converted pulse data
11 Buffer Memory (Parameters & Monitored Data)
→ For details on the acceleration time, refer to Section 7.2
Description
→ For details on the deceleration time, refer to Section 7.2
Description
Description
Description
*1
11.1 Positioning Parameters
Default
K200
Default
K200
Default
K100
Default
K4,000,000
*1
.
→ Refer to Section 7.7