Electrical Safety Guidelines And Warnings; General Electrical Safety Guidelines And Warnings - Juniper EX2200 Hardware Manual

Hide thumbs Also See for EX2200:
Table of Contents

Advertisement

CHAPTER 24

Electrical Safety Guidelines and Warnings

General Electrical Safety Guidelines and Warnings

Copyright © 2016, Juniper Networks, Inc.
TN Power Warning on page 259
This topic applies to hardware devices in the EX Series product family, which includes
EX Series switches, the EX Series Redundant Power System (RPS), and the XRE200
External Routing Engine.
This topic also applies to hardware devices in the QFX Series, to OCX1100 switches, and
to NFX250 devices.
WARNING:
Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP)
cabling. To comply with NEBS requirements and protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not
be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The addition of primary
protectors is not sufficient protection for connecting these interfaces
metallically to OSP wiring.