Connecting and Configuring an EX Series Switch (CLI Procedure)

Copyright © 2016, Juniper Networks, Inc.
}
}
ethernet-switching-options {
storm-control {
interface all;
}
}
Configuration Files Terms
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 167
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 170
Understanding Configuration Files for EX Series Switches
EX2200 Switches Hardware Overview on page 3
There are two ways to connect and configure an EX Series switch: one method is through
the console by using the CLI and the other is by using the J-Web interface.
NOTE:
EX2200-24T-4G-DC switches do not support switch connection and
configuration through the J-Web interface.
This topic describes the CLI procedure.
NOTE:
To run the
configuration as the active configuration. If you have configured anything on
the switch and want to run
See Reverting to the Default Factory Configuration for the EX Series Switch.
Using the CLI, set the following parameter values in the console server or PC:
Baud rate—9600
Flow control—None
Data—8
Parity—None
Stop bits—1
DCD state—Disregard
Chapter 14: Performing Initial Configuration
script, the switch must have the factory-default
ezsetup
, revert to the factory-default configuration.
ezsetup
167