Table 48: Parts and Tools Required for Connecting an EX Series Switch to Earth Ground

Earthing
Terminal
Switch
Location
EX2200
Rear panel
of the
chassis
EX2300-C
Rear panel
of the
chassis
EX2300
Rear panel
of the
chassis
EX3200
Rear panel
of the
chassis
EX3300
Rear panel
of the
chassis
EX3400
Rear panel
of the
chassis
144
for connecting a switch to earth ground. Before you begin connecting a switch to earth
ground, ensure you have the parts and tools required for your switch.
Grounding Cable
Grounding Lug
Requirements
Specifications
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
14 AWG (2 mm²),
Panduit
minimum 90°C
LCC10-14BWL or
wire, or as
equivalent—
permitted by the
not provided
local code
Screws and
Washers
Screwdriver
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—
not provided
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—
not provided
Two 10-32 x .25 in.
Phillips (+)
screws with #10
number 2
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Copyright © 2016, Juniper Networks, Inc.
Additional
Information
See
"Special
Instructions
to Follow
Before
Connecting
Earth Ground
to a Switch"
on page
146.