Addr.
Setting Title
3111
3I0>>>
3112
T 3I0>>>
3113
3I0>>> Telep/BI
3114
3I0>>>SOTF-Trip
3115
3I0>>>InrushBlk
3120
Op. mode 3I0>>
3121
3I0>>
3122
T 3I0>>
3123
3I0>> Telep/BI
3124
3I0>> SOTF-Trip
3125
3I0>> InrushBlk
3130
Op. mode 3I0>
3131
3I0>
3131
3I0>
3132
T 3I0>
3133
3I0> Telep/BI
3134
3I0> SOTF-Trip
3135
3I0> InrushBlk
3140
Op. mode 3I0p
3141
3I0p PICKUP
3141
3I0p PICKUP
3142
3I0p MinT-DELAY
3143
3I0p Time Dial
3144
3I0p Time Dial
3145
3I0p Time Dial
3146
3I0p MaxT-DELAY
7SA6 Manual
C53000-G1176-C133-1
Function
Setting Options
Earth fault overcur-
0.50..25.00 A
rent
0.00..30.00 sec; ∞
Earth fault overcur-
rent
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
Forward
rent
Reverse
Non-Directional
Inactive
Earth fault overcur-
0.20..25.00 A
rent
0.00..30.00 sec; ∞
Earth fault overcur-
rent
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
Forward
rent
Reverse
Non-Directional
Inactive
Earth fault overcur-
0.05..25.00 A
rent
Earth fault overcur-
0.003..25.000 A
rent
0.00..30.00 sec; ∞
Earth fault overcur-
rent
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
Forward
rent
Reverse
Non-Directional
Inactive
Earth fault overcur-
0.05..25.00 A
rent
Earth fault overcur-
0.003..25.000 A
rent
Earth fault overcur-
0.00..30.00 sec
rent
0.05..3.00 sec; ∞
Earth fault overcur-
rent
0.50..15.00; ∞
Earth fault overcur-
rent
0.05..15.00 sec; ∞
Earth fault overcur-
rent
Earth fault overcur-
0.00..30.00 sec
rent
Default Setting
4.00 A
3I0>>> Pickup
0.30 sec
T 3I0>>> Time delay
NO
Instantaneous trip via Teleprot./BI
NO
Instantaneous trip after SwitchOnTo-
Fault
NO
Inrush Blocking
Inactive
Operating mode
2.00 A
3I0>> Pickup
0.60 sec
T 3I0>> Time Delay
NO
Instantaneous trip via Teleprot./BI
NO
Instantaneous trip after SwitchOnTo-
Fault
NO
Inrush Blocking
Inactive
Operating mode
1.00 A
3I0> Pickup
1.000 A
3I0> Pickup
0.90 sec
T 3I0> Time Delay
NO
Instantaneous trip via Teleprot./BI
NO
Instantaneous trip after SwitchOnTo-
Fault
NO
Inrush Blocking
Inactive
Operating mode
1.00 A
3I0p Pickup
1.000 A
3I0p Pickup
1.20 sec
3I0p Minimum Time Delay
0.50 sec
3I0p Time Dial
5.00
3I0p Time Dial
1.35 sec
3I0p Time Dial
5.80 sec
3I0p Maximum Time Delay
Appendix
Comments
B-13