Siemens siprotec 7SA6 User Manual page 156

Distance protection
Hide thumbs Also See for siprotec 7SA6:
Table of Contents

Advertisement

Configuration
Table 5-3
Overview of indications via the system interface
Information Type ↓ \Message Buffer →
Single Point Indications (SP)
Double Point Indications (DP)
Output Indications (OUT)
Internal Single Point Indications (IntSP)
Internal Double Point Indications (DP)
Command with/without Feedback (C_**)
Measurement Value (MV)
Measurement Value with Time (MVT)
Measurement Value, User Defined (MVU)
Pulse Metered Value (PMV)
Configuring CFC
as a Destination
Configuring the
System Interface as
a Destination
Configuring the
Default and Control
Display as a
Destination
Configuring the
Control as a
Destination
Configuring the
Measured Value
Window as a
Destination
Configuring the
Metered Value
Window as a
Destination
Retrieving Device
Configurations
from the Device
Front
5-32
Single point, double point, and output indications, as well as limit and measured
values, may be configured to CFC as the destination.
The information listed in Table 5-3 can be allocated according to the type of the system
interface. Setting an „X" in the matrix cell the information is transferred via the system
interface to its connected components.
Except for thresholds all informations can be allocated into both the default and the
control display. By setting an "X" in the matrix cell the information can be used in the
default and control display.
Single point and double point indications as well as all types of commands can be
allocated to the control as a destination. Thus they are available for the operational
control in the display of the device and the DIGSI
In addition to the measured values available in the relay, user defined measured and
limit values may be configured into the measured value window. These values also
become available in the device display in the corresponding measured value window
®
4 Menu 0HDVXUHPHQW.
and in the DIGSI
User defined pulse values and metered values derived from the measured values may
be configured into the metered value window so that they may be displayed at the front
relay panel. They are then available in the corresponding measured value window in
the display of the device.
Retrieving the configurations is also possible from the device front. You may access
configuration information under 0DLQ 0HQX: → 6HWWLQJV → 0DVNLQJ ,2 .
The menu title 0$6.,1* ,2 appears in the title bar. Configuration information re-
garding each (physical) input and output is indicated in the display.
Any new user defined information is also shown in the display once loaded into the
®
relay from DIGSI
4.
IEC
Profibus
X
X
X
X
X
X
®
4 Menu &RQWURO
X
X
X
X
X
X
X
X
X
X
7SA6 Manual
C53000-G1176-C133-1