7.5.2
RFID Error and Reset Timing
Error signal output with one-shot pulse
Read/Write error
RFID tag error output
Error signal output with long pulse
Read/Write error
RFID tag error output
Print end (Print done)
(Type2)
When the reprint count reaches the specified number, the RFID tag error and Machine error are
outputted at a time. The machine error output is always a long pulse.
100 - 500 ms