The types of errors to print are as follows:
Message
TAG NOT FOUND
WRITE TAG ERROR
PROTECT (TAG)
ERROR
VERIFY TAG
ERR(OR)
LOCKING ERROR
WRONG TID ERROR
MULTI TAGS ERROR
DIFFER EPC ERROR
Cause and Countermeasure
Cause:
Did not find the tag to print, or failed to read the tag.
Countermeasure:
Confirm the inlay operation and check the printer/antenna
configuration.
Cause:
Failed to write the tag.
Countermeasure:
Confirm the inlay operation and check the printer/antenna
configuration.
Cause:
1. Tried to write to a locked tag.
2. Tried to write to an address that is not permitted.
Countermeasure:
Use media that is not locked.
• Only for ISO/IEC 15693, ISO/IEC 14443 Type A
Cause:
The written data and read data do not match.
Countermeasure:
Confirm the inlay operation and check the printer/antenna
configuration.
• Only for FeliCa
Cause:
The written data and read data do not match. A value
greater than original data was written to subtraction register.
Countermeasure:
Write an appropriate value to subtraction register.
Cause:
Failed to lock the tag.
Countermeasure:
Check the media.
• Only for ISO/IEC 15693
Cause:
Read the UID of the tag other than the specified tag.
Countermeasure:
Check the tag type setting and the label.
• Only for ISO/IEC 15693, ISO/IEC 14443 Type A
Cause:
Multiple tags detected at a time.
Countermeasure:
Confirm the inlay operation and check the printer/antenna
configuration.
• Only for FeliCa
Cause:
The captured IDm of the card is inconsistent between
processes. (Tried to write to a wrong card.)
Countermeasure:
Confirm the inlay operation and check the printer/antenna
configuration.
• Only for UHF
Cause:
Detected inconsistent EPC during a series of processes.
Countermeasure:
Check the media.