Sensor (document tray width 2) removal

1. Open the ADF left cover assembly.
2. Lift the document tray assembly.
3. Remove the five screws securing the cover (A).
4. Remove the cover (A).
5. Remove the two screws securing the bracket (B).
6. Remove the bracket (B).
7. Remove the connector from the sensor (document tray width 2) (C).
8. Release the hooks securing the sensor (document tray width 2) (C).
9. Remove the sensor (document tray width 2) (C).
Note: The sensor (document tray width 1), sensor (document tray width 2), or the sensor (document tray
width 3) are all identical.
4-168