7510
Scanner removals
Scanner unit assembly removal
1. Remove the platen cushion assembly. See
2. Remove the ADF unit assembly. See
3. Remove the operator panel assembly. See
4. Disconnect all connections from the scanner unit assembly (A).
5. Remove the two rear screws securing the scanner unit assembly (A) to the machine.
6. Remove the two screws securing the two brackets (B) to the machine.
7. Remove the two brackets (B).
8. Remove the scanner unit assembly (A).
4-122
Service Manual
"Platen cushion removal" on page
"ADF unit assembly removal" on page
"Operator panel assembly removal" on page
4-137.
4-136.
4-126.