Step
7
Check the image density sensor assembly for toner
contamination.
Is the above component dirty or contaminated?
8
Re-Perform the Skew fine setup.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Control setup cycles
5. Touch Skew fine setup
Does the above test pass?
9
Re-Perform the Skew fine setup.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Control setup cycles
5. Touch Skew fine setup
Does the above test pass?
Check
Yes
Remove and clean
Go to step 8.
the image density
sensor assembly.
See
"Image
density sensor
assembly
removal" on
page
4-55.
Perform the In/Out
Replace the image
setup.
density sensor
assembly.
See
"In/out
setup" on
See
"Image
page
4-272.
density sensor
assembly
removal" on
page
4-55.
Perform the In/Out
Contact next level
setup.
of support.
See
"In/out
setup" on
page
4-272.
Repair information
7510
Previous
No
Next
Go Back
4-271