Lexmark X945e MFP 7510 series Service Manual page 701

Hide thumbs Also See for X945e MFP 7510 series:
Table of Contents

Advertisement

Step
3
Analyze the fine skew setup.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Control setup cycles
5. Touch Cycle result values
Locate the following new values for the following settings:
Patch-B in
Patch-B out
Is the value for both of the above settings a "4"?
4
Perform the skew rough setup.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Control setup cycles
5. Touch Skew rough setup
Does the above test pass?
Check
Yes
Go to step 4.
Go to step 6.
Go to step 5.
Go to step 6.
Repair information
7510
Previous
No
Next
Go Back
4-269