Field Service Ver. 2.0 Mar. 2006
17.9.4
Foolscap Size Setting
Functions
• To set the size for Foolscap paper.
Use
• Upon setup.
• To change the size for Foolscap paper.
Setting/
• Select the size from among the following five.
Procedure
220 x 330 mm
17.9.5
Install Date
Functions
• To register the date the main unit was installed.
Use
• Upon setup.
Setting/
1. Call the Service Mode on the screen.
Procedure
2. Select the key as follows.
[System 1] → [Install Date].
3. Enter the date (Year 4 digit → Month 2 digit → date 2 digit) from the 10-Key Pad.
4. Click [Entry] to set the date of installation.
17.9.6
Initialization
A. Data Clear
Functions
• To initialize the setting data.
Use
• To clears the setting data.
• For details on items to be cleared, "Contents to be cleared by Reset function."
See P.283
NOTE
• When removing or installing the hard disk after registering the data below, be
sure to clear the data.
Referring data: One-Touch Registration, User Authentication/Account Track.
Setting/
1. Call the Service Mode on the screen.
Procedure
2. Select the key as follows.
[System 1] → [Initialization] → [Data clear].
3. Press the Start key.
4. When [OK] is displayed, turn off the Main Power Switch and turn it on again more
than 10 seconds after.
B. System Error Clear
Functions
• To reset the trouble data.
Use
• Use to clear the [Jam], [Trouble], [Error] displays, and other improper displays.
• For details on items to be cleared, "Contents to be cleared by Reset function."
See P.283
Setting/Pro-
1. Call the Service Mode on the screen.
cedure
2. Select the key as follows.
[System 1] → [Initialization] → [System Error Clear].
3. Press the Start key.
4. When [OK] is displayed, turn off the Main Power Switch and turn it on again more
than 10 seconds after.
8 1/2 x 13
8 1/4 x 13
17. Jig Soft
8 1/8 x 13 1/4
8 x 13
249