6. Service Mode
6.
Service Mode
6.1
Service Mode setting procedure
See P.434 of the main body service manual.
6.2
ADF setting procedure
6.2.1
Original Stop Position
Functions
• To manually adjust the original stop position and the read position in each of the ADF
modes.
Use
• When the result is Unable in the automatic adjustment of the original stop position.
Setting/
P.40
procedure
6.2.2
Registration Loop Adj.
Functions
• To adjust the length of the loop to be formed in paper before the registration rollers.
Use
• When an original misfeed or skew occurs.
Adjustment
• The loop value increases by the entered + value and decreases by the entered - value.
instructions
Adjustment
• The default setting is 0.
range
• Adjustable range: -5 mm to + 5 mm (in 1-mm increments)
1. Call the Service Mode to the screen.
2. Touch [ADF].
3. Touch [Registration Loop Adj].
4. Select either [1-Side] or [Second Side] for the adjustment.
Setting/
5. Press the clear key and change the setting value using the 10-key pad. (Press the [+/-]
procedure
key to change the +/- code.)
6. Touch [END].
7. Touch [Exit] on the Service Mode screen.
8. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
6.2.3
Auto Stop Position Adjustment
A. Sub Scanning Direction 1-Side
Functions
• To automatically adjust the read position for the Sub Scanning Direction 1-Side.
• To check skew feed.
Use
• When ADF has been replaced.
Setting/
P.36
procedure
B. Sub Scanning Direction 2-Side
Functions
• To automatically adjust the read position for the Sub Scanning Direction 2-Side.
Use
• When ADF has been replaced.
Setting/
P.38
procedure
28
Field Service Ver. 5.0 Jan. 2008