8. Mechanical adjustment
5
[1]
[5]
[4]
84
5
[1]
[2]
A07RF3C540DA
A
[2]
A07RF3C541DA
A
[3]
[1]
[2]
A07RF3C542DA
Field Service Ver. 7.0 Jun. 2008
A. For FS-517/FS-518
5. Check to see if the actuator [2] of the
alignment home sensor /Up [1] is
aligned with the home position.
6. Check to see if the distance A
between the alignment plate /Up [1]
and the panel /Rr [2] is within a stan-
dard value.
Standard value: A = 41.2 ± 0.5 mm
7. When the value is not within the
standard value, perform the following
adjustment.
8. Loosen two screws [1] and adjust the
distance between the alignment
plate /UpRr [2] and the panel /Rr [3]
in accordance with the standard
value, and the secure it.
9. Loosen two screws [4] and adjust the
position of the alignment plate /UpFr
[5] to make the distance to the align-
ment plate /UpRr [2] be the standard
value.
Standard value: A = 335.5
+1.5
mm