Field Service Ver. 7.0 Jun. 2008
[1]
[4]
[1]
[2]
[1]
A07RF3C543DA
A07RF3C544DA
[2]
[1]
[2]
[3]
A07RF3C545DA
8. Mechanical adjustment
B. For FS-608
5. Check to see if the actuator [2] of the
alignment home sensor /Up [1] is
aligned with the home position.
6. Check to see if the distance A
between the alignment plates /Up [1]
is within a standard value.
Standard value: A = 335.5
7. When the value is not within the
standard value, perform the following
adjustment.
8. Loosen two screws [1] and adjust the
alignment plate /UpRr [2] with the
long center marking [3] of the mark-
ing lines, and then adjust the position
of the alignment plate /UpFr [4] by
referring the back side to make the
distance be the standard value.
+0
mm
-0.5
85