Field Service Ver. 7.0 Jun. 2008
10.2.11
C1109: Stapler F unit drive failure
Stapler unit
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of each motor for
2
proper drive coupling, and correct as nec-
essary.
3
Staple unit replacement
4
FSDB replacement
5
FSCB replacement
10.2.12
C1110: Stapler R unit drive failure
Stapler unit
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of each motor for
2
proper drive coupling, and correct as nec-
essary.
3
Staple unit replacement
4
FSDB replacement
5
FSCB replacement
Relevant electrical parts
FNS drive board (FSDB)
FNS control board (FSCB)
Action
Relevant electrical parts
FNS drive board (FSDB)
FNS control board (FSCB)
Action
10. Malfunction code
WIRING DIAGRAM
Control signal
—
—
—
—
—
WIRING DIAGRAM
Control signal
—
—
—
—
—
Location
(Electrical
component)
—
—
—
—
—
Location
(Electrical
component)
—
—
—
—
—
127