Field Service Ver. 6.0 May 2008
10.2.7
C1105: Paper exit drive failure
Paper exit motor (M8)
paper exit home sensor (PS12)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of each motor for
2
proper drive coupling, and correct as nec-
essary.
5
3
PS12 I/O, sensor check
5
4
M8 operation check
5
FSCB replacement
10.2.8
C1106: Stapler movement drive failure
Stapler movement motor (M11)
Stapler movement home sensor (PS11)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of each motor for
2
proper drive coupling, and correct as nec-
essary.
5
3
PS11 I/O, sensor check
5
4
M11 operation check
5
FSDB replacement
6
FSCB replacement
Relevant electrical parts
FNS control board (FSCB)
Action
Relevant electrical parts
FNS control board (FSCB)
FNS drive board (FSDB)
Action
10. Malfunction code
WIRING DIAGRAM
Control signal
—
—
FSCB CN7<B>-8 (ON)
FSCB CN8<B>-3 to 4
—
WIRING DIAGRAM
Control signal
—
—
FSDB CN27<A>-11 (ON)
FSDB CN26-1 to 6
—
—
Location
(Electrical
component)
—
—
FS-517/518/608
C-3
FS-517/518/608
C-5
—
Location
(Electrical
component)
—
—
FS-517/518/608
P to Q-12
FS-517/518/608
P to Q-11
—
—
125