Field Service Ver. 8.0 Jun. 2008
16.5.83
C4101: Polygon motor rotation trouble
PH unit
Step
Check the connector for proper connection
1
and correct as necessary.
2
Change PH unit
3
Change REYB/PH
4
Change PRCB
16.5.84
C4301: PH cooling fan motor failure to turn
PH cooling fan motor (FM14)
Step
Check the FM14 connector for proper con-
1
nection and correct as necessary.
Check the fan for possible overload and
2
correct as necessary.
3
FM14 operation check
4
Change FM14
5
Change REYB/PH
6
Change DCPU
Relevant parts
Action
Relevant parts
Action
PH relay board (REYB/PH)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
PH relay board (REYB/PH)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
REYB PH CN4REYB PH-1
(REM)
REYB PH CN4REYB PH-3
(LOCK)
—
—
—
16. Malfunction code
Location (Electri-
cal component)
—
—
—
—
Location (Electri-
cal component)
—
—
B-7
—
—
—