Field Service Ver. 3.0 May 2007
3.3.9
Lift-up motor
1. Remove the right cover.
See P.10
2. Remove the rear cover.
See P.12
[1]
3.3.10
Dehumidification heater
1. Remove the right cover.
See P.10
[1]
[2]
[3]
A03NF2C512DA
[1]
[2]
A03NF2C042DA
[2]
A03NF2C043DA
3. Disconnect the connector [1],
remove three screws [2] and remove
the lift-up motor [3].
2. Remove the harness from the con-
nector [1] and three wire saddles [2].
3. Remove four screws [1] and remove
the dehumidification heater [2].
3. Other
27