6. Mechanical adjustment
6.
Mechanical adjustment
6.1
Adjusting the paper reference position
6.1.1
Centering
1. Call the Service Mode to the screen.
See P.434 of the main body service manual.
2. Touch [Machine].
3. Touch [Printer Area].
4. Touch [Centering].
5. Touch [LCT].
6. Press the Start key to let the machine produce a test print.
8. If the measured width A falls outside the specified range, enter the correction value
using the [-] or [+] key.
9. Produce another test print and check to see if width A falls within the specified range.
10. If the use of the [-] or [+] key does not allow the measurement to fall within the specified
range, perform the following steps.
34
A
A03NF3C502DA
Field Service Ver. 3.0 May 2007
7. Measure the width of printed refer-
ence line A.
Specification: 3.0 mm ± 1.0 mm
A03NF3E509DA