8.2.5
C1134: Main motor cooling fan drive failure
Main motor cooling fan (FM1)
Step
Check the FM1 connector for proper con-
1
nection and correct as necessary.
Check the fan for possible overload and
2
correct as necessary.
3
FM1 operation check
4
Change FM1
5
Change ZUCB
8.2.6
C1135: Punch motor drive failure
Punch motor (M4)
Step
Check the M4 connector for proper con-
1
nection and correct as necessary.
Check the connector of M4 for proper
2
drive coupling and correct as necessary.
4
M5 operation check
5
Change M5
6
Change ZUCB
58
Relevant electrical parts
ZU control board (ZUCB)
Action
Relevant electrical parts
ZU control board (ZUCB)
Action
Field Service Ver. 2.0 May 2008
WIRING DIAGRAM
Control signal
—
—
ZUCB CN11-11 (DRV)
ZUCB CN11-12 (EN)
—
—
WIRING DIAGRAM
Control signal
—
—
ZUCB CN5-1 to 6
—
—
Location
(Electrical
component)
—
—
C-8
—
—
Location
(Electrical
component)
—
—
C-1 to 2
—
—