Optical Section; Detaching And Refitting The Exposure Lamp - Kyocera KM-3035 Service Manual

Hide thumbs Also See for KM-3035:
Table of Contents

Advertisement

1-6-3 Optical section

(1) Detaching and refitting the exposure lamp

Replace the exposure lamp as follows.
Procedure
1. Remove the original cover or the DP.
2. Remove the upper right cover, upper front
cover, upper rear cover and contact glass.
3. Move the mirror 1 frame to the cutouts of the
machine.
Caution: When moving the mirror 1 frame, do
not touch the exposure lamp nor the inverter
PCB.
4. Remove the two screws holding the metal
plate on the rear of the machine and then the
plate.
5. Detach the exposure lamp connector from the
inverter PCB.
6. Remove the two screws holding the exposure
lamp and then the lamp.
7. Replace the exposure lamp and refit all the
removed parts.
2FD/2FF/2FG
Contact glass
Upper rear cover
Upper right cover
Figure 1-6-26
Metal plate
Figure 1-6-27
Exposure lamp
Connector
Figure 1-6-28
1-6-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-4035Km-5035

Table of Contents