Field Service Ver. 1.0 Aug. 2005
4.5.2

Replacing the Bypass Tray Separation Roller Assy

1. Remove the Multi Bypass Unit.
71
[1]
[5]
[3]
[6]
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
[2]
4037F2C515DA
[4]
4037F2C522DA
4. Periodical check
2. Remove two screws [1], and remove
Bypass Paper Separation Roller fix-
ing bracket Assy [2].
3. Snap off the C-clip [3], and remove
the spring [4] and the guide plate [5].
Remove the Bypass Paper Separa-
tion Roller Assy [6].
4. To reinstall, reverse the order of
removal.
5. Select [Tech. Rep. Mode] →
[Counter] → [Special Parts Counter]
→ [Bypass] and clear the counter.
NOTE
• Replace the Bypass Feed Roller
and the Bypass Separation Roller
Assy at the same time.