21. Image quality problem
21.3.6

Scanner System: White streaks or bands

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Original
2
Original Cover
3
4
Shading Sheet
5
Mirrors/Lens/
Original Glass/
Reflectors
6
Exposure Lamp
7
BCRS Board
8
258
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
4036fs4021c0
Check Item
Original is damaged or dirty.
Original Pad is dirty.
Original Cover does not lie flat.
Shading sheet is dirty.
Mirrors, lens, Original Glass and/or
reflectors are dirty.
Exposure Lamp is dirty.
The problem has been eliminated after
performing step 6.
The white lines or bands are blurry or
opaque.
Field Service Ver. 1.0 Aug. 2005
4036fs4022c0
Result
Action
YES
Change original.
YES
Clean.
YES
Replace Original Cover if
it is deformed or the
hinges are broken.
YES
Clean.
YES
Clean.
YES
Clean.
Change Exposure Lamp.
NO
Change the Jumper
Switch Setting on the
BCRS Board.
218
YES
Change Exposure Unit.
Change CCD Unit.