Software Sw Setting For Cs Remote Care - Konica Minolta bizhub 250 Service Manual

Mfp
Hide thumbs Also See for bizhub 250:
Table of Contents

Advertisement

11. Tech. Rep. Mode
11.11.3

Software SW setting for CS Remote Care

NOTE
• In case you changed bit data by accident, be sure to restore the previous state.
A. Input procedure
1. Select [
Tech. Rep. Mode
Switch Setting].
2. Touch [Mode Selection], and input the SW number (two digits) using the 10-Key Pad.
3. Touch [Bit Selection], and select SW bit number using the arrow keys, and input 0 or 1
using the 10-Key Pad.
(For setting by hexadecimal numbers, touch [HEX Selection], and input using the 10-
Key Pad or A to F keys.)
4. Touch [Enter].
NOTE
• About functions of each switch, see to "B. List of software SW for CS Remote
Care."
B. List of software SW for CS Remote Care
NOTE
• Do not change any bit not described on this table.
SW No.
Bit
SW 01
0
Dial Mode
1
Reservation
2
Reservation
3
Reservation
4
Baud rate
5
6
7
SW 02
0
Emergency transmission
1
Date specified transmission
2
Reservation
3
Reservation
4
Reservation
5
Auto call on the IC Life
6
Reservation
7
Reservation
SW 03
0
Reservation
1
Auto call on the toner empty
2
Reservation
3
Reservation
4 to 7 Reservation
SW 04
0 to 7 Reservation
180
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
] → [CS Remote Care] → [Detail Setting], and touch [Software
Functions
Field Service Ver. 1.0 Aug. 2005
0
1
Pulse
Tone
*1
*1
*1
*1
*1
*1
*1
*1
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Default
1
0
0
0
0
0
0
1
1
1
0
0
0
1
1
0
0
1
0
1
0
0

Hide quick links: