Field Service Ver. 1.0 Aug. 2005
3.3.5
Replacing the Replace Stamp 2
[1]
[3]
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
1. Open the Upper Door [1].
2. Open the Processing Guide [2].
[2]
4344F2C534DA
3. Remove the stamp.
4. Reinstall the new Replace Stamp 2
[4]
[3].
NOTE
• Align the protrusion of the stamp to
the crevice of the holder.
[5]
5. Close the Processing Guide.
6. Close the Upper Door.
4344F2C537DA