4. Periodical check
4.5

Maintenance procedure (Periodical check parts)

4.5.1

Replacing the Bypass Tray Feed Roller

1. Remove the Multi Bypass Unit.
71
[1]
[2]
[3]
[6]
[8]
18
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
[1]
4037F2C518DA
[4]
4040F2C708DA
[5]
4040F2C506DA
[7]
4037F2C520DA
Field Service Ver. 1.0 Aug. 2005
2. Remove five screws [1] and the Man-
ual Bypass Unit Lower Frame [2].
3. Remove two screws [3] and the Feed
Roller Cover [4].
4. Snap off the C-clip [5] for the Feed
Roller, and remove the bearing. [6].
5. Snap off the C-clip [7], and remove
the Bypass Feed Roller [8].
6. To reinstall, reverse the order of
removal.
7. Select [Tech. Rep. Mode] →
[Counter] → [Special Parts Counter]
→ [Bypass] and clear the counter.
NOTE
• Replace the Bypass Feed Roller
and the Bypass Separation Roller
Assy at the same time.