6.5.10

Replacing the manual bypass tray separation roller assy

A. Periodically replacing parts/cycle
• Manual bypass tray separation roller assy: Every 200,000 prints
B. Procedure
1. Remove the manual bypass tray unit.
See P.111
[2]
[1]
[1]
[2]
A02EF2C023DA
A02EF2C024DA
[1]
[2]
A02EF2C025DA
6. Periodical check
2. Remove two springs [1] and the
guide plate [2].
3. Remove the screw [1], and remove
the ground terminal [2].
4. Remove the screw [1], and remove
the manual bypass tray separation
roller assy [2].